Nexans 400TBG Tee connector

Products

AMV-C-K400TBG-15/025-095S(3)

Nexans ref. 10197014

  • Packaging: Unit (3Unit)
  • Diameter over insulation, range: 16 ... 26.5 mm
  • Conductor cross-section, range: 25 ... 50 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

AMV-C-K400TBG-21/095-300S(3)

Nexans ref. 10179612

  • Packaging: Unit (3Unit)
  • Diameter over insulation, range: 22 ... 34.6 mm
  • Conductor cross-section, range: 95 ... 300 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

AMV-C-K400TBGE-15/025-095S(3)

Nexans ref. 10510456

  • Packaging: Unit (3Unit)
  • Diameter over insulation, range: 16 ... 26.5 mm
  • Conductor cross-section, range: 25 ... 95 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

AMV-C-K400TBGE-21/095-300S(3)

Nexans ref. 10510459

  • Packaging: Unit (3Unit)
  • Diameter over insulation, range: 22 ... 34.6 mm
  • Conductor cross-section, range: 95 ... 300 mm²
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

AMV-C-M400TBG-21/050-150S(3)

Nexans ref. 10185825

  • Packaging: Unit (3Unit)
  • Diameter over insulation, range: 22 ... 34.6 mm
  • Conductor cross-section, range: 50 ... 150 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

AMV-C-M400TBG-27/095-300S(3)

Nexans ref. 10153741

  • Packaging: Unit (3Unit)
  • Diameter over insulation, range: 28.5 ... 37.5 mm
  • Conductor cross-section, range: 95 ... 300 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

AMV-C-M400TBGE-21/050-150S(3)

Nexans ref.

  • Packaging: Unit (3Unit)
  • Diameter over insulation, range: 22 ... 34.6 mm
  • Conductor cross-section, range: 50 ... 150 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

AMV-C-M400TBGE-27/095-300S(3)

Nexans ref.

  • Packaging: Unit (3Unit)
  • Diameter over insulation, range: 28.5 ... 37.5 mm
  • Conductor cross-section, range: 95 ... 300 mm²
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV

 

Description

Description

Standards

  • Test
    CENELEC HD 629.1

Delivery

  • Plug housing with integrated control electrode and thick-walled, conductive outer skin with ground connection wire
  • Insulation termination with conductive end cap
  • Cable Adapter
  • Bolt and conductor contact
  • Silicon grease
  • Shield seal
  • Assembly Instructions

Optionally:

  • Fixing Bride

When ordering specify:

  • Cable type
  • Diameter over insulation
  • Shield design, desired shield connection
  • Conductor cross-section, material and class

Characteristics

Characteristics

Resources

Resources

Documentation

Selling & delivery Information

When ordering specify:

  • Cable type
  • Diameter over insulation
  • Shield design, desired shield connection
  • Conductor cross-section, material and class

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close