GKN-ALU 1 X 150 Alrm/30 Cu 0.6/1 kV
GKN-ALU 1 X 150 Alrm/30 Cu 0.6/1 kV
LV underground distibution single core cable with cross-linked HEPR insulation and concentric copper-wire conductor.
Read more- Nexans ref. : 10504436
- EAN : 7611755582913
Description
Description
Standards
-
InternationalHD 603; IEC 60228
-
NationalASE
LV underground distribution single core cables with aluminium conductor, cross-linked HEPR insulation and concentric copper-wire conductor.
Applications
- Low voltage distribution networks underground.
- Poses tubes, gutters, cable trays and in earth.
- Arises in electrical substations.
Cable construction
- Aluminium conducteur
- Cross-linked HEPR insulation
- Extruded filler
- Concentric copper wire conductor
- Outer PE sheath
Other versions on request
- Execution with flame retardened filler and sheath material
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Aluminum
Conductor shape
Circular
Conductor flexibility
Stranded class 2
Insulation
HEPR
Number of conductors
1
Core identification
Black
Material of the outer core / screen
Copper wires
Outer core type
Waveform concentric
Outer sheath
PE
Sheath colour
Black + 2 yellow lines
Halogen free
Yes
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
150 mm²
Conductor diameter
14.4 mm
Diameter over insulation
17.0 mm
Screen section
30 mm²
Diameter over external conductor / metallic screen
22.3 mm
Nominal outer diameter
26.1 mm
Approximate weight
104.0 kg/100m
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
0,6/1 kV
Maximum operating voltage
1 kV
Perm. current rating in air 30°C - trefoil formation
330 A
Perm. current rating buried 20°C - trefoil formation
290 A
Nominal phase capacitance
- µF / km
Impedance (AC) at max. operating temperature
- Ohm
Phase reactance 50 Hz - trefoil formation
0.07 Ohm/km
Max. DC resistance of the conductor at 20°C
0.206 Ohm/km
I max. @ 60°C-buried, flat, spaced, earthing 1pt, LF1
- A
I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627
231 A
I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1
214.9 A
I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1
298.7 A
I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627
298.4 A
I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1
276.8 A
I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1
430.3 A
Mechanical characteristics
Mechanical characteristics
Maximum pulling force by laying
4.5 kN
Usage characteristics
Usage characteristics
Bending factor when laying
12 (xD)
Bending factor when installed
10 (xD)
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Resources
Resources
Declaration of Performance
- Declaration of Performance n� : 1000378-CHCD
- Certification Date : 3/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 4
- Declared performance : Fca