GKN 3 X 10/10 Cure 0.6/1 kV
GKN 3 X 10/10 Cure 0.6/1 kV
LV underground distibution cable with cross-linked HEPR insulation and concentric copper-wire conductor.
Read more- Nexans ref. : 10152847
- EAN : 7611755065614
Description
Description
Standards
-
InternationalHD 603; IEC 60228
-
NationalASE
Applications
- Underground distribution networks
- Pipe laying and ground laying
- Installation in electrical substations
Construction
- Copper or aluminium conductor
- Cross-linked HEPR insulation
- Assembly of insulated conductors
- Extruded filler
- Ceander concentric conductor made of copper wire
- Black PE outer sheath with 2 yellow longitudinal stripes
Properties
- Cross-linked insulation with high resistance to high operating temperatures in case of overload and short circuit.
- No release of corrosive gases = safe installation
- Outer sheath made of specially abrasion-resistant PE with low shrinkage rate.
- No interruption of the protective conductor when making a branch
- Halogen-free
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Copper
Conductor shape
Circular
Conductor flexibility
Solid class 1
Insulation
HEPR
Number of conductors
3
Core identification
Black, red, white
Material of the outer core / screen
Copper wires
Outer core type
Waveform concentric
Outer sheath
PE
Sheath colour
Black + 2 yellow lines
Halogen free
Yes
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
10 mm²
Conductor diameter
3.5 mm
Diameter over insulation
4.8 mm
Screen section
10 mm²
Diameter over external conductor / metallic screen
13.5 mm
Nominal outer diameter
17.1 mm
Approximate weight
55.0 kg/100m
Auxiliary cable diameter
- mm
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
0,6/1 kV
Maximum operating voltage
1 kV
Perm. current rating in air 30°C - trefoil formation
74 A
Perm. current rating buried 20°C - trefoil formation
69 A
Nominal phase capacitance
0.238 µF / km
Impedance (AC) at max. operating temperature
2.334 Ohm
Phase reactance 50 Hz - trefoil formation
0.08 Ohm/km
Max. DC resistance of the conductor at 20°C
1.83 Ohm/km
I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627
56.1 A
I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1
53.9 A
I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1
52.6 A
I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627
71.6 A
I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1
68.9 A
I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1
75.3 A
Mechanical characteristics
Mechanical characteristics
Maximum pulling force by laying
1.2 kN
Usage characteristics
Usage characteristics
Bending factor when laying
10 (xD)
Bending factor when installed
8 (xD)
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Minimum installation temperature
-5 °C
Resources
Resources
Documentation
Accessories - GKN 3x10 10 Cure
pdf — 97.8 kB
Declaration of Performance
- Declaration of Performance n� : 1000377-CHCD
- Certification Date : 3/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 4
- Declared performance : Fca
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania