XDALT-YT 3x1x 95 Al/32 mm² 12/20 kV
XDALT-YT 3x1x 95 Al/32 mm² 12/20 kV
Medium voltage 20 kV single-core cables with cross-linked PE insulation (XLPE) and aluminium screen tape.
Read more- Nexans ref. : 10507147
- EAN : 7611755557256
Description
Description
Standards
-
ProductHD 620; IEC 60502
-
NationalASE
Applications
- Underground distribution networks
- Pipe laying and ground laying
- Installation in electrical substations
Construction
- Round copper or aluminium conductor
- Extruded inner conductor
- Cross-linked PE insulation (XLPE)
- Extruded outer semi-conductor
- Semi-conductive swelling tape
- Laminated aluminium tape screen
- Black PE outer sheath, with 2 red longitudinal stripes
- Three-pole construction:
- Assembly of three monopolar cables
- Outer sheath in HDPE
Properties
- Longitudinal sealing by two layers of tape which swell in the presence of moisture and prevent the spread of water in the event of an injury to the sheath
- Radial sealing provided by the laminated aluminium tape
- Special abrasion resistant PE outer jacket with low shrinkage rate
- Cross-linked PE insulation (XLPE) with high dielectric strength and low losses
- Halogen free
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor flexibility
Class 2
Conductor material
Aluminum
Conductor shape
Round compacted
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
95 mm²
Conductor diameter
11.6 mm
Average insulation thickness
4.8 mm
Diameter over insulation
22.2 mm
Screen section
32 mm²
Diameter over external conductor / metallic screen
24.6 mm
Average sheath thickness
1.5 mm
Nominal outer diameter
64.2 mm
Approximate weight
267.8 kg/100m
Number of cores
3
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
12/20 kV
Maximum operating voltage
24 kV
Max. DC resistance of the conductor at 20°C
0.32 Ohm/km
I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1
176 A
I max. @ 60°C-buried, trefoil, joined, earthing 2pts, LF1
175 A
I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1
201 A
I max. @ 60°C-in the air inside, trefoil, joined, earthing 2pts, LF1
201 A
I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1
226 A
I max. @ 90°C-buried, trefoil, joined, earthing 2pts, LF1
226 A
I max. @ 90°C-in the air inside, trefoil, joined, earthing 1pt, LF1
287 A
I max. @ 90°C-in the air inside, trefoil, joined, earthing 2pts, LF1
287 A
Impedance at 50Hz and 90°C
0.39 Ohm/km
Nominal inductance
0.39 mH/km
Nominal phase capacitance
0.247 µF / km
Permissible short circuit current conductor 0.5s
13 kA
Permissible short circuit current conductor 1s
9.3 kA
Permissible short circuit current screen 0.5s
3.3 kA
Permissible short circuit current screen 1s
2.4 kA
Phase reactance 50 Hz - trefoil formation
0.121 Ohm/km
Mechanical characteristics
Mechanical characteristics
Maximum pulling force by laying
5.7 kN
Usage characteristics
Usage characteristics
Minimum installation temperature
-5 °C
Bending factor when laying
12 (xD)
Bending factor when installed
8 (xD)
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Resources
Resources
Documentation
Accessories - XDALT-YT 1x95 Al
pdf — 145.5 kB
Declaration of Performance
- Declaration of Performance n� : 1000391-CHCD
- Certification Date : 3/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 4
- Declared performance : Fca
Related products
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania