SIWO-KUL B10 1x240 1,1KV YE

Description

Description

Standards

  • Product
    CSA C22.2 N° 210-05; EN 45545 - HL3; IEC 60228; UL 758
  • Installation
    IEC 60092
  • Test
    IEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034

Application

  • Connection of rotating machines windings, like motors, alternators, generators.
  • Cabling of static devices, like power converters, motor drives, power cabinets, transformers
  • Adapted for wind turbines, marine and offshore, rollingstock, photovoltaic, energy storage systems

Construction

  • Flexible tin-plated copper conductor class 5 as per IEC 60228, other class in option
  • High grade silicon rubber insulation
  • Mechanical protection by PUR varnished synthetic fibre braid for enhanced friction resistance

Properties

  • Operating temperature in continuous mode -55°C to +180°C
  • Resistance to thermal shocks, UV and oils
  • Enhanced friction resistance with the PUR varnished range
  • Compatibility to VPI impregnation resins

 

  • Type approval certificate : Lloyds Register LR21139304TA
  • Type approval certificate : BV Marine & Offshore 09555/D0 BV, file : ACE 01/723/01
  • Certificate of compliance : UL758 AWM Style 3640, file : AVLV2.E45073
  • Certificate of compliance : CSA Standard C22.2 N°210-15, file : LL 36040 AWM

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Outer sheath
Synthetic yarn braiding
Conductor flexibility
Flexible class 5
Conductor material
Tinned copper
Construction type
1120 x 0.5
Halogen free
Yes
Insulation
Special Silicone

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
240 mm²
Nominal outer diameter
26.9 mm
Conductor diameter
21.8 mm
Approximate weight
2284 kg/km

Electrical characteristics

Electrical characteristics

Operating voltage
1.1 kV
Test voltage
5 kV
Max. DC resistance of the conductor at 20°C
0.082 Ohm/km
Breakdown voltage
10 kV
Dielectric constant relative value (indicative)
3.50
Loss factor tan d
< 10-2
Breakdown field strength (kV/mm)
> 20

Mechanical characteristics

Mechanical characteristics

Minimum Tensile Strength
8 MPa
Cable flexibility
Flexible
Elongation at break of insulation (%)
> 250

Usage characteristics

Usage characteristics

Maximum operating temperature
180 °C
Minimum operating temperature
-55 °C
Chemical resistance
Fire resistant
IEC 60331
Fire retardant
IEC 60332-3
Flame retardant
IEC 60332-1
Gases corrosivity
IEC 60754-1; IEC 60754-2
Minimum static operating bending radius
136.5 mm
Oil resistance
Yes
Operating temperature, range
-55 ... 180 °C
Ozone resistance
Yes
Packaging
Cut to length
Smoke density
IEC 61034
U.V resistance
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close