Nexans SIWO-KUL® S30 12 kV
Nexans SIWO-KUL® S30 12 kV
SIWO-KUL® S30 12 kV cables are designed with a COPPER braid SCREEN to avoid EMC interference with SILICONE sheath
Read moreSIWO-KUL S30 1x16 12 kV BK
Nexans ref. 10581072
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Nominal outer diameter: 21.8 mm
SIWO-KUL S30 1x25 12 kV BK
Nexans ref. 10207759
- Packaging: Cut to length (m)
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 21.9 mm
SIWO-KUL S30 1x35 12 kV BK
Nexans ref. 10549497
- Packaging: Cut to length (m)
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 24.2 mm
SIWO-KUL S30 1x50 12 kV BK
Nexans ref. 10224688
- Packaging: Cut to length (m)
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 25.9 mm
SIWO-KUL S30 1x70 12 kV BK
Nexans ref. 10560244
- Packaging: Cut to length (m)
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 27.9 mm
SIWO-KUL S30 1x95 12 kV BK
Nexans ref. 60011923
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 29.6 mm
SIWO-KUL S30 1x120 12 kV BK
Nexans ref. 10567757
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 31.5 mm
SIWO-KUL S30 1x150 12 kV BK
Nexans ref. 10581240
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 34.9 mm
SIWO-KUL S30 1x185 12 kV BK
Nexans ref. 60500695
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 35.6 mm
SIWO-KUL S30 1x240 12 kV BK
Nexans ref. 60012240
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 37.8 mm
Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092
-
TestIEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034
Application
- Connection of rotating machines windings, like motors, alternators, generators.
- Cabling of static devices, like power converters, motor drives, power cabinets, transformers
- Adapted for wind turbines, marine and offshore, rollingstock, photovoltaic, energy storage systems
Construction
- Flexible tin-plated copper conductor class 5 as per IEC 60228, other class in option
- High grade silicon rubber insulation
- Tin platted Cu braid for EMC protection screen
- Silicone outer sheath
- Inner and outer co-extruded semi-conductor reduces partial discharge and increases cable life
Properties
- Partial discharge < 10 pC
- Operating temperature in continuous mode -55°C to +180°C
- Resistance to thermal shocks
- Type approval certificate : Lloyds Register LR21139304TA
- Type approval certificate : BV Marine & Offshore 09555/D0 BV, file : ACE 01/723/01
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Halogen free
Yes
Electrical characteristics
Electrical characteristics
Operating voltage
12 kV
Usage characteristics
Usage characteristics
Operating temperature, range
-55 ... 180 °C
Chemical resistance
Good
Oil resistance
Yes
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Fire resistant
IEC 60331
Gases corrosivity
IEC 60754-1; IEC 60754-2
Smoke density
IEC 61034
Resources