Nexans SIWO-KUL® S30 12 kV

Products

SIWO-KUL S30 1x16 12 kV BK

Nexans ref. 10581072

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: 21.8 mm

 

SIWO-KUL S30 1x25 12 kV BK

Nexans ref. 10207759

  • Packaging: Cut to length (m)
  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 21.9 mm

 

SIWO-KUL S30 1x35 12 kV BK

Nexans ref. 10549497

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 24.2 mm

 

SIWO-KUL S30 1x50 12 kV BK

Nexans ref. 10224688

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 25.9 mm

 

SIWO-KUL S30 1x70 12 kV BK

Nexans ref. 10560244

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 27.9 mm

 

SIWO-KUL S30 1x95 12 kV BK

Nexans ref. 60011923

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 29.6 mm

 

SIWO-KUL S30 1x120 12 kV BK

Nexans ref. 10567757

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 31.5 mm

 

SIWO-KUL S30 1x150 12 kV BK

Nexans ref. 10581240

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 34.9 mm

 

SIWO-KUL S30 1x185 12 kV BK

Nexans ref. 60500695

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 35.6 mm

 

SIWO-KUL S30 1x240 12 kV BK

Nexans ref. 60012240

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 37.8 mm

 

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092
  • Test
    IEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034

Application

  • Connection of rotating machines windings, like motors, alternators, generators.
  • Cabling of static devices, like power converters, motor drives, power cabinets, transformers
  • Adapted for wind turbines, marine and offshore, rollingstock, photovoltaic, energy storage systems

Construction

  • Flexible tin-plated copper conductor class 5 as per IEC 60228, other class in option
  • High grade silicon rubber insulation
  • Tin platted Cu braid for EMC protection screen
  • Silicone outer sheath
  • Inner and outer co-extruded semi-conductor reduces partial discharge and increases cable life

Properties

  • Partial discharge < 10 pC
  • Operating temperature in continuous mode -55°C to +180°C
  • Resistance to thermal shocks

 

  • Type approval certificate : Lloyds Register LR21139304TA
  • Type approval certificate : BV Marine & Offshore 09555/D0 BV, file : ACE 01/723/01

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Halogen free
Yes

Electrical characteristics

Electrical characteristics

Operating voltage
12 kV

Usage characteristics

Usage characteristics

Operating temperature, range
-55 ... 180 °C
Chemical resistance
Good
Oil resistance
Yes
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Fire resistant
IEC 60331
Gases corrosivity
IEC 60754-1; IEC 60754-2
Smoke density
IEC 61034

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close