Nexans AIN Indoor slip-on termination
AMV-J-AIN 24.1/25-95SM12(3)
Nexans ref. 10184446
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 18 ... 23.5 mm
- Conductor cross-section, range: 25 ... 95 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 24.2/95-240SM12(3)
Nexans ref. 10184447
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 22.5 ... 33 mm
- Conductor cross-section, range: 95 ... 240 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 24.2/95-240SM16(3)
Nexans ref. 10189546
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 22.5 ... 33 mm
- Conductor cross-section, range: 95 ... 240 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 24.3/300-400SM16(3)
Nexans ref. 10184448
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 27.3 ... 37.6 mm
- Conductor cross-section, range: 300 ... 400 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 24.3/400-500SM16(3)
Nexans ref. 10179373
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 31 ... 41 mm
- Conductor cross-section, range: 400 ... 500 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 24.4/400-630SM16(3)
Nexans ref. 10184449
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 34 ... 46 mm
- Conductor cross-section, range: 400 ... 630 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 24.5/630-800SM20(3)
Nexans ref. 10500945
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 39 ... 50 mm
- Conductor cross-section, range: 630 ... 800 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 24.6/1000SM20(3)
Nexans ref. 10500946
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 46 ... 58 mm
- Conductor cross-section, range: 1000 ... 1000 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 24.6/1200SM20(3)
Nexans ref. 10500947
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 46 ... 58 mm
- Conductor cross-section, range: 1200 ... 1200 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AIN 36.1/50-95SM12(3)
Nexans ref. 10501186
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 23.5 ... 29 mm
- Conductor cross-section, range: 50 ... 95 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AIN 36.2/95-240SM12(3)
Nexans ref. 10504446
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 27 ... 38 mm
- Conductor cross-section, range: 95 ... 240 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AIN 36.2/95-240SM16(3)
Nexans ref. 10225053
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 27 ... 38 mm
- Conductor cross-section, range: 95 ... 240 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AIN 36.3/240-400SM16(3)
Nexans ref. 10213280
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 32 ... 43 mm
- Conductor cross-section, range: 240 ... 400 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AIN 36.5/400-630SM16(3)
Nexans ref. 10501182
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 39 ... 50 mm
- Conductor cross-section, range: 400 ... 630 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AIN 36.6/630-1000SM20(3)
Nexans ref. 10501184
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper wires
- Diameter over insulation, range: 12.7 ... 21 mm
- Conductor cross-section, range: 630 ... 1000 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AINE 24.1/25-95SM12(3)
Nexans ref. 10501197
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 18 ... 23.5 mm
- Conductor cross-section, range: 25 ... 95 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 24.2/95-240SM12(3)
Nexans ref. 10501200
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 22.5 ... 33 mm
- Conductor cross-section, range: 95 ... 240 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 24.2/95-240SM16(3)
Nexans ref. 10501201
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 22.5 ... 33 mm
- Conductor cross-section, range: 95 ... 240 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 24.3/300-400SM16(3)
Nexans ref. 10504447
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 31 ... 41 mm
- Conductor cross-section, range: 300 ... 400 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 24.3/400-500SM16(3)
Nexans ref. 10504448
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 31 ... 41 mm
- Conductor cross-section, range: 400 ... 500 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 24.4/400-630SM16(3)
Nexans ref. 10504449
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 34 ... 46 mm
- Conductor cross-section, range: 400 ... 630 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 24.5/630-800SM20(3)
Nexans ref. 10504450
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 39 ... 50 mm
- Conductor cross-section, range: 630 ... 800 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 24.6/1000SM20(3)
Nexans ref. 10504451
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 46 ... 58 mm
- Conductor cross-section, range: 1000 ... 1000 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 24.6/1200SM20(3)
Nexans ref. 10504452
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 46 ... 58 mm
- Conductor cross-section, range: 1200 ... 1200 mm²
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
AMV-J-AINE 36.1/50-95SM12(3)
Nexans ref. 10504453
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 23.5 ... 29 mm
- Conductor cross-section, range: 50 ... 95 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AINE 36.2/95-240SM12(3)
Nexans ref. 10504454
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 27 ... 38 mm
- Conductor cross-section, range: 95 ... 240 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AINE 36.2/95-240SM16(3)
Nexans ref. 10504455
- Packaging: Set (3Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 27 ... 38 mm
- Conductor cross-section, range: 95 ... 240 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AINE 36.3/240SM16(1)
Nexans ref. 10501317
- Packaging: Set (Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 32 ... 43 mm
- Conductor cross-section, range: 240 ... 240 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AINE 36.5/400SM16(1)
Nexans ref. 10501318
- Packaging: Set (Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 39 ... 50 mm
- Conductor cross-section, range: 400 ... 400 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
AMV-J-AINE 36.6/630SM16(1)
Nexans ref. 10501330
- Packaging: Set (Kit)
- Material of the outer core / screen: Copper or aluminium tape
- Diameter over insulation, range: 46 ... 58 mm
- Conductor cross-section, range: 400 ... 630 mm²
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV