RW-BA PE-ALT-CLT 1X4/1,53 SW
RW-BA PE-ALT-CLT 1X4/1,53 SW
Balise cable for ETCS railway networks
- Nexans ref. : 10178681
Description
Description
Standards
-
TestIEC 60754-1; IEC 60754-2
Preferential use
- cable for ETCS balise railway networks
- Siemens CH + DE Approved
Key-points
- for connecting ETCS balise
- according to SBB I-AT-FS 3001.52.2000 specifications
- according to Siemens MKA 815.1 specifications
- Low reduction factor
- Rodent protection
- radial water protection (moisture barrier)
Cable construction
- Conductor: Bare Copper wire
- Insulation: polyethylene
- Stranding
- Screen: Aluminium/polyethylene coated tape longitudinally applied and overlapped
- Intermediate sheath: polyethylene
- Armour: Two galvanized steel tapes
- Outer sheath: Black polyethylene
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Armour type
Galvanized steel tapes
Conductor material
Bare copper
Halogen free
Yes
Inner sheath
Polyethylene
Insulation
Solid polyethylene
Outer sheath
PE
Protection
-
Screen
Aluminium coated tape
Sheath colour
Black
Dimensional characteristics
Dimensional characteristics
Conductor diameter
1.53 mm
Nominal outer diameter
17.1 mm
Precision of diameter
+/- 0.7 mm
Approximate weight
326 kg/km
Electrical characteristics
Electrical characteristics
Dielectric strength core to core DC, min.
2.5 kV
Dielectric strength core to screen DC, min.
2.5 kV
Usage characteristics
Usage characteristics
Weather resistance
Good
Water proof
Radial
Minimum operating temperature
-30 °C
Maximum operating temperature
70 °C
Minimum installation temperature
-5 °C
Resources
Resources
Documentation
Declaration of Performance
- Declaration of Performance n� : 1000484-CHCD
- Certification Date : 3/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 4
- Declared performance : Fca
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania