SW 3x (4/1,50) PE-T-CLT

Description

Description

Standards

  • Test
    IEC 60754-1; IEC 60754-2; IEC 61034

Applications
Copper signalling cable for railways. These cables are used for line blocks, signalling, control and monitoring.

Construction

  • Conductor : Copper
  • Insulation : Polyethylene
  • Armouring : Double steel tapes
  • Sheathing : Black PE LLD

Properties

  • Class CPR Fca
  • Cable approved by SBB (3001.82.1000)
  • Protection against rodents

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Galvanized steel tapes, light (CL)
Insulation
PE
Outer sheath
PE LLD

Dimensional characteristics

Dimensional characteristics

Number of quads
3
Conductor diameter
1.5 mm
Outer Diameter
20.9 mm
Approximate weight
0.53 kg/m

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
-
Maximum admissible traction load (Tm)
170 daN

Usage characteristics

Usage characteristics

Field of application
Outdoor
Installation type
Cableway cables
Water proof
No
Minimum installation temperature
-10 °C
Maximum operating temperature
60 °C
Minimum bending radius, static (XD)
10

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000487-CHCD
  • Certification Date : 3/1/23
  • AVCP (Assessment and Verification of Constancy of Performance) : System 4
  • Declared performance : Fca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close