Microduct Unitube FO

Products

LE 4/T4 B-Lite G657A1

Nexans ref.

  • Packaging: Cut to length (m)
  • Nominal outer diameter: 2.4 mm
  • Number of optical fibres: 4
  • Maximum admissible traction load (Tm): 10 daN
  • Maximum tensile load during service (Tl): 4.0 daN
  • Crush resistance (IEC 60794-1-E3): 200 N/cm
  • Operating temperature, range: -25 ... 70 °C

 

LE 12/T12 B-Lite G657A1

Nexans ref.

  • Packaging: Cut to length (m)
  • Nominal outer diameter: 2.4 mm
  • Number of optical fibres: 12
  • Maximum admissible traction load (Tm): 10 daN
  • Maximum tensile load during service (Tl): 4.0 daN
  • Crush resistance (IEC 60794-1-E3): 200 N/cm
  • Operating temperature, range: -25 ... 70 °C

 

LE 12/T12 DKT G657A1

Nexans ref. 10510476

  • Packaging: Cut to length (m)
  • Nominal outer diameter: 3.9 mm
  • Number of optical fibres: 12
  • Maximum admissible traction load (Tm): 60 daN
  • Maximum tensile load during service (Tl): 20.0 daN
  • Crush resistance (IEC 60794-1-E3): 150 N/cm
  • Operating temperature, range: -30 ... 60 °C

 

LE 24/T24 DKT G657A1

Nexans ref. 10510477

  • Packaging: Cut to length (m)
  • Nominal outer diameter: 3.9 mm
  • Number of optical fibres: 24
  • Maximum admissible traction load (Tm): 60 daN
  • Maximum tensile load during service (Tl): 20.0 daN
  • Crush resistance (IEC 60794-1-E3): 150 N/cm
  • Operating temperature, range: -30 ... 60 °C

 

Description

Description

Standards

  • International
    IEC 60793; IEC 60794

Preferential use

  • FTTH project
  • For deployement between last manhole and the building’s entry point.

 

Key-points

  • Suitable to be blown in microducts (type 5.5/7 mm)
  • High blowing distance due to the excellent friction properties of the outer sheath
  • Right balance between flexibility and rigidity
  • Waterproof structure
  • All dielectric design
  • Fibre count (12 or 24 fibres)

 

Applications

  • Suitable to be blown in microducts (type 5.5/7 mm)
  • Laying in cableway
  • Suitable for blowing

 

Construction

  • Jelly filled central  tube
  • Swisscom colorcode
  • Aramid yarns reinforcement
  • Very Low friction outer sheath PEHD

 

Installation

  • Set cutter blade at 0.45 mm
  • Cut the outer jacket at 10 cm of the end and remove it to access to the aramid yarns
  • Using an aramid yarns as a ripcord, cut the outer sheath and remove it
  • Cut the aramid yarns

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Aramid yarn
Fiber optic type
G.657A

Usage characteristics

Usage characteristics

Installation type
Outdoor - Microduct blowable
Ambient installation temperature, range
-10 ... 40 °C
Storage temperature, range
-40 ... 70 °C

Resources

Resources

Documentation

Selling & delivery Information

Standard Marking

Nexans - FIBRE OPTIC CABLE - XX*YY - metric


XX = Fibre Count
YY = Fibre Type

Special Marking

on request

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close