Low voltage single core distribution cables type GKN-ALU
Low voltage single core distribution cables type GKN-ALU
LV underground distribution single core cables with cross-linked HEPR insulation and concentric copper-wire conductor
Read moreGKN-ALU 1 X 150 Alrm/30 Cu 0.6/1 kV
Nexans ref. 10504436
- Packaging: m
- Conductor cross-section: 150 mm²
- Perm. current rating in air 30°C - trefoil formation: 330 A
- Perm. current rating buried 20°C - trefoil formation: 290 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 231 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 214.9 A
- I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 298.7 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 298.4 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 276.8 A
- I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 430.3 A
GKN-ALU 1 X 240 Alrm/50 Cu 0.6/1 kV
Nexans ref. 10507374
- Packaging: m
- Conductor cross-section: 240 mm²
- Perm. current rating in air 30°C - trefoil formation: 450 A
- Perm. current rating buried 20°C - trefoil formation: 380 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 313.3 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 289.1 A
- I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 411.3 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 405 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 372.5 A
- I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 591 A
GKN-ALU 1 X 300 Alrm/70 Cu 0.6/1 kV
Nexans ref. 10217964
- Packaging: m
- Conductor cross-section: 300 mm²
- Perm. current rating in air 30°C - trefoil formation: 520 A
- Perm. current rating buried 20°C - trefoil formation: 440 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 356 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 327.5 A
- I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 476.8 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 460.4 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 422.2 A
- I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 685.6 A
Description
Description
Standards
-
InternationalHD 603; IEC 60228
-
NationalASE
LV underground distribution single core cables with aluminium conductor, cross-linked HEPR insulation and concentric copper-wire conductor.
Applications
- Low voltage distribution networks underground.
- Poses tubes, gutters, cable trays and in earth.
- Arises in electrical substations.
Cable construction
- Aluminium conducteur
- Cross-linked HEPR insulation
- Extruded filler
- Concentric copper wire conductor
- Outer PE sheath
Other versions on request
- Execution with flame retardened filler and sheath material
Characteristics
Characteristics
Electrical characteristics
Electrical characteristics
I max. @ 60°C-buried, flat, spaced, earthing 1pt, LF1
- A
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania