Low voltage cables type GKN Cu

Products

GKN 3 X 10/10 Cure 2LN 0.6/1 kV

Nexans ref. 10152848

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 10 mm²
  • Perm. current rating in air 30°C - trefoil formation: 74 A
  • Perm. current rating buried 20°C - trefoil formation: 69 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 56.1 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 53.9 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 52.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 71.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 68.9 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 75.3 A

 

GKN 3 X 10/10 Cure 0.6/1 kV

Nexans ref. 10152847

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 10 mm²
  • Perm. current rating in air 30°C - trefoil formation: 74 A
  • Perm. current rating buried 20°C - trefoil formation: 69 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 56.1 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 53.9 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 52.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 71.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 68.9 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 75.3 A

 

GKN 3 X 10/10 Curm stranded 0.6/1 kV

Nexans ref. 10152850

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 10 mm²
  • Perm. current rating in air 30°C - trefoil formation: 76 A
  • Perm. current rating buried 20°C - trefoil formation: 69 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 56.2 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 54 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 53.3 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 71.9 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 69.1 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 76.1 A

 

GKN 3 X 16/16 Curm stranded 0.6/1 kV

Nexans ref. 10152852

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 16 mm²
  • Perm. current rating in air 30°C - trefoil formation: 101 A
  • Perm. current rating buried 20°C - trefoil formation: 90 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 74.1 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 71.1 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 70.4 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 94.9 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 90.9 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 100.7 A

 

GKN 3 X 25/25 Curm stranded 0.6/1 kV

Nexans ref. 10152854

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 25 mm²
  • Perm. current rating in air 30°C - trefoil formation: 133 A
  • Perm. current rating buried 20°C - trefoil formation: 115 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 95.3 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 91.2 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 93.1 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 122.1 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 116.7 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 132.6 A

 

GKN 3 X 50/50 Curm stranded 0.6/1 kV

Nexans ref. 10152855

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 50 mm²
  • Perm. current rating in air 30°C - trefoil formation: 200 A
  • Perm. current rating buried 20°C - trefoil formation: 170 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 137.7 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 131.1 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 140.2 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 176.7 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 168.1 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 200.2 A

 

GKN 3 X 6/6 Cure 2LN 0.6/1 kV

Nexans ref. 10152845

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 6 mm²
  • Perm. current rating in air 30°C - trefoil formation: 55 A
  • Perm. current rating buried 20°C - trefoil formation: 51 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 42.3 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 40.8 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 38.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 54 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 52 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 55 A

 

GKN 3 X 6/6 Cure 0.6/1 kV

Nexans ref. 10152843

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 6 mm²
  • Perm. current rating in air 30°C - trefoil formation: 55 A
  • Perm. current rating buried 20°C - trefoil formation: 51 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 42.3 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 40.8 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 38.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 54 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 52 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 55 A

 

GKN 3 X 95/95 Curm stranded 0.6/1 kV

Nexans ref. 10152858

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 95 mm²
  • Perm. current rating in air 30°C - trefoil formation: 308 A
  • Perm. current rating buried 20°C - trefoil formation: 252 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 207.4 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 196.3 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 215.7 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 266.8 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 252.2 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 307.9 A

 

GKN 3 X 150 Cu/95 mm² 0.6/1 kV

Nexans ref. 10152859

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 150 mm²
  • Perm. current rating in air 30°C - trefoil formation: 408 A
  • Perm. current rating buried 20°C - trefoil formation: 323 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 268 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 252.5 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 287.2 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 345.2 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 324.8 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 410.4 A

 

GKN 3 X 150/150 Curm stranded 0.6/1 kV

Nexans ref. 10152860

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 150 mm²
  • Perm. current rating in air 30°C - trefoil formation: 408 A
  • Perm. current rating buried 20°C - trefoil formation: 323 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 267.3 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 251.9 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 286.1 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 344.2 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 324 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 408.2 A

 

GKN 3 X 240/240 Curm stranded 0.6/1 kV

Nexans ref. 10152862

  • Packaging: m
  • Number of conductors: 3
  • Conductor cross-section: 240 mm²
  • Perm. current rating in air 30°C - trefoil formation: 547 A
  • Perm. current rating buried 20°C - trefoil formation: 433 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 356 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 333.4 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 384.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 459.1 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 429.5 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 547.2 A

 

GKN 4 X 150/150 Curm 0.6/1 kV

Nexans ref. 10511682

  • Packaging: m
  • Number of conductors: 4
  • Conductor cross-section: 150 mm²
  • Perm. current rating in air 30°C - trefoil formation: 408 A
  • Perm. current rating buried 20°C - trefoil formation: 323 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 272.3 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 255.9 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 294.1 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 350.2 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 330 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 419.2 A

 

GKN 4 X 16/16 Curm 0.6/1 kV

Nexans ref. 10511460

  • Packaging: m
  • Number of conductors: 4
  • Conductor cross-section: 16 mm²
  • Perm. current rating in air 30°C - trefoil formation: 101 A
  • Perm. current rating buried 20°C - trefoil formation: 90 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 76.1 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 73.1 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 72.4 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 96.9 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 92.9 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 103.7 A

 

GKN 4 X 240/240 Curm 0.6/1 kV

Nexans ref. 10562669 - Country ref. Switzerland

  • Packaging: Cut to length (m)
  • Number of conductors: 4
  • Conductor cross-section: 240 mm²
  • Perm. current rating in air 30°C - trefoil formation: 579 A
  • Perm. current rating buried 20°C - trefoil formation: 417 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 362 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 338.4 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 396.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 467.1 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 436.5 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 566.2 A

 

GKN 4 X 25/25 Curm 0.6/1 kV

Nexans ref. 10511397

  • Packaging: m
  • Number of conductors: 4
  • Conductor cross-section: 25 mm²
  • Perm. current rating in air 30°C - trefoil formation: 133 A
  • Perm. current rating buried 20°C - trefoil formation: 115 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 98.3 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 93.2 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 96.1 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 124.1 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 118.7 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 136.6 A

 

GKN 4 X 50/50 Curm 0.6/1 kV

Nexans ref. 10512330

  • Packaging: m
  • Number of conductors: 4
  • Conductor cross-section: 50 mm²
  • Perm. current rating in air 30°C - trefoil formation: 200 A
  • Perm. current rating buried 20°C - trefoil formation: 170 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 140.7 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 133.1 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 145.2 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 180.7 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 172.1 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 207.2 A

 

GKN 4 X 95/95 Curm 0.6/1 kV

Nexans ref. 10511681

  • Packaging: m
  • Number of conductors: 4
  • Conductor cross-section: 95 mm²
  • Perm. current rating in air 30°C - trefoil formation: 308 A
  • Perm. current rating buried 20°C - trefoil formation: 252 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 212.4 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 200.3 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 222.7 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 272.8 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 257.2 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 316.9 A

 

GKN 4 X 10/10 Cure 3LN 0.6/1 kV

Nexans ref. 10510792

  • Packaging: m
  • Number of conductors: 4
  • Conductor cross-section: 10 mm²
  • Perm. current rating in air 30°C - trefoil formation: 74 A
  • Perm. current rating buried 20°C - trefoil formation: 69 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 57.1 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 54.9 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 53.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 72.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 70.9 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 77.3 A

 

GKN 4 X 10/10 Curm 3LN 0.6/1 kV

Nexans ref. 10564611

  • Packaging: m
  • Number of conductors: 4
  • Conductor cross-section: 10 mm²
  • Perm. current rating in air 30°C - trefoil formation: 76 A
  • Perm. current rating buried 20°C - trefoil formation: 69 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 57.2 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 55 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 54.3 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 72.9 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 71.1 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 78.1 A

 

GKN 4 X 6/6 Cure 0.6/1 kV

Nexans ref. 10512716

  • Packaging: m
  • Number of conductors: 4
  • Conductor cross-section: 6 mm²
  • Perm. current rating in air 30°C - trefoil formation: 55 A
  • Perm. current rating buried 20°C - trefoil formation: 51 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 43.3 A
  • I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 41.8 A
  • I max. @ 60°C-in the air inside, flat, spaced, earthing 1pt, LF1: 39.6 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 55 A
  • I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF1: 53 A
  • I max. @ 90°C-in the air inside, flat, spaced, earthing 1pt, LF1: 57 A

 

Description

Description

Standards

  • International
    HD 603; IEC 60228
  • National
    ASE

Applications

  • Underground distribution networks
  • Pipe laying and ground laying
  • Installation in electrical substations

Construction

  • Copper or aluminium conductor
  • Cross-linked HEPR insulation
  • Assembly of insulated conductors
  • Extruded filler
  • Ceander concentric conductor made of copper wire
  • Black PE outer sheath with 2 yellow longitudinal stripes

Properties

  • Cross-linked insulation with high resistance to high operating temperatures in case of overload and short circuit.
  • No release of corrosive gases = safe installation
  • Outer sheath made of specially abrasion-resistant PE with low shrinkage rate.
  • No interruption of the protective conductor when making a branch
  • Halogen-free

Characteristics

Characteristics

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close