Nexans XDALT-YT XLPE insulated MV cable

Products

XDALT-YT 3x1x 50 Al/28 mm² 12/20 kV NEW

Nexans ref. 10507146

  • Packaging: m
  • Conductor cross-section: 50 mm²

 

XDALT-YT 3x1x 50 Cu/28 mm² 12/20kV NEW

Nexans ref. 10507129

  • Packaging: m
  • Conductor cross-section: 50 mm²

 

XDALT-YT 3x1x 95 Al/32 mm² 12/20 kV NEW

Nexans ref. 10507147

  • Packaging: m
  • Conductor cross-section: 95 mm²

 

XDALT-YT 3x1x 95 Cu/32 mm² 12/20kV NEW

Nexans ref. 10507130

  • Packaging: m
  • Conductor cross-section: 95 mm²

 

XDALT-YT 3x1x150 Al/35 mm² 12/20 kV NEW

Nexans ref. 10507148

  • Packaging: m
  • Conductor cross-section: 150 mm²

 

XDALT-YT 3x1x150 Cu/35 mm² 12/20kV NEW

Nexans ref. 10507131

  • Packaging: m
  • Conductor cross-section: 150 mm²

 

XDALT-YT 3x1x240 Al/39 mm² 12/20 kV NEW

Nexans ref. 10507149

  • Packaging: m
  • Conductor cross-section: 240 mm²

 

XDALT-YT 3x1x240 Cu/39 mm² 12/20kV NEW

Nexans ref. 10507132

  • Packaging: m
  • Conductor cross-section: 240 mm²

 

XDALT-YT 3x1x300 Cu/44 mm² 12/20kV NEW

Nexans ref. 10507133

  • Packaging: m
  • Conductor cross-section: 300 mm²

 

Description

Description

Standards

  • Product
    HD 620; IEC 60502
  • National
    ASE

Applications

  • Underground distribution networks
  • Pipe laying and ground laying
  • Installation in electrical substations

Construction

  • Round copper or aluminium conductor
  • Extruded inner conductor
  • Cross-linked PE insulation (XLPE)
  • Extruded outer semi-conductor
  • Semi-conductive swelling tape
  • Laminated aluminium tape screen
  • Black PE outer sheath, with 2 red longitudinal stripes
  • Three-pole construction:
  • Assembly of three monopolar cables
  • Outer sheath in HDPE

Properties

  • Longitudinal sealing by two layers of tape which swell in the presence of moisture and prevent the spread of water in the event of an injury to the sheath
  • Radial sealing provided by the laminated aluminium tape
  • Special abrasion resistant PE outer jacket with low shrinkage rate
  • Cross-linked PE insulation (XLPE) with high dielectric strength and low losses
  • Halogen free

Characteristics

Characteristics

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close