Nexans XKDT XLPE insulated MV cable
Nexans XKDT XLPE insulated MV cable
Medium voltage 20 kV single-core cables with cross-linked PE insulation (XLPE) and copper-wire screen.
Read moreXKDT 1x 25 Cu/10 mm² 12/20 kV
Nexans ref. 10152573
- Packaging: m
- Conductor cross-section: 25 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 105.9 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 118 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 112.5 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 144.7 A
XKDT 1x 50 Al/10 mm² 12/20 kV
Nexans ref. 10221202
- Packaging: m
- Conductor cross-section: 50 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 113.5 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 132 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 120.8 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 155.3 A
XKDT 1x 50 Cu/16 mm² 12/20kV
Nexans ref. 10152574
- Packaging: m
- Conductor cross-section: 50 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 149.8 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 172 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 159.9 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 205.9 A
XKDT 1x 95 Al/16 mm² 12/20 kV
Nexans ref. 10152605
- Packaging: m
- Conductor cross-section: 95 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 172.8 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 201 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 185.8 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 239.4 A
XKDT 1x 95 Cu/25 mm² 12/20kV
Nexans ref. 10152575
- Packaging: m
- Conductor cross-section: 95 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 222.6 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 259 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 239.4 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 308.8 A
XKDT 1x150 Al/25 mm² 12/20 kV
Nexans ref. 10152606
- Packaging: m
- Conductor cross-section: 150 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 220.1 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 263 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 237.5 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 306.3 A
XKDT 1x150 Cu/35 mm² 12/20kV
Nexans ref. 10152576
- Packaging: m
- Conductor cross-section: 150 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 283.6 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 339 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 306.1 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 395.3 A
XKDT 1x240 Al/35 mm² 12/20 kV
Nexans ref. 10152607
- Packaging: m
- Conductor cross-section: 240 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 289.9 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 359 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 314.4 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 405.6 A
XKDT 1x240 Cu/35 mm² 12/20kV
Nexans ref. 10152577
- Packaging: m
- Conductor cross-section: 240 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 377 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 459 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 409.9 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 530.5 A
XKDT 1x300 Al/35 mm² 12/20 kV
Nexans ref. 10216057
- Packaging: m
- Conductor cross-section: 300 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 328.4 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 413 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 357.2 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 461 A
XKDT 1x300 Cu/35 mm² 12/20kV
Nexans ref. 10152579
- Packaging: m
- Conductor cross-section: 300 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 426.4 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 529 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 465.1 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 602.5 A
XKDT 1x400 Al/35 mm² 12/20 kV
Nexans ref. 10152608
- Packaging: m
- Conductor cross-section: 400 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 375.5 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 479 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 409.4 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 528.9 A
XKDT 1x400 Cu/50 mm² 12/20kV
Nexans ref. 10152581
- Packaging: m
- Conductor cross-section: 400 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 482.6 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 606 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 527.9 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 685.2 A
XKDT 1x500 Al/35 mm² 12/20 kV
Nexans ref. 10168129
- Packaging: m
- Conductor cross-section: 500 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 438 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 669 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 480.8 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 622.2 A
XKDT 1x500 Cu/50 mm² 12/20kV
Nexans ref. 10152582
- Packaging: m
- Conductor cross-section: 500 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 558.8 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 698 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 614.6 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 800.6 A
XKDT 1x630 Cu/70 mm² 12/20kV
Nexans ref. 10152584
- Packaging: m
- Conductor cross-section: 630 mm²
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF1: 632.4 A
- I max. @ 60°C-in the air inside, trefoil, joined, earthing 1pt, LF1: 802 A
- I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627: 699.1 A
- I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627: 912.8 A
Description
Description
Standards
-
ProductHD 620 S2 P10N; IEC 60228 Class 2 ; IEC 60502
Applications
- Underground distribution networks
- Pipe laying and ground laying
- Installation in electrical substations
Construction
- Round copper or aluminium conductor
- Extruded inner conductor
- Cross-linked PE insulation (XLPE)
- Extruded outer semi-conductor
- Semi-conductive swelling tape
- SZ concentric copper wire screen
- Swelling tape
- Black PE outer sheath, with 2 red longitudinal lines
Properties
- Longitudinal sealing by two layers of tapes which swell in the presence of moisture and prevent the spread of water in the event of a damage to the sheath
- Outer jacket made of specially abrasion-resistant PE with a low shrinkage rate
- Cross-linked PE insulation (XLPE) with high dielectric strength and low losses
- Halogen-free
admissible load MV cables
Currents are indicative and given for normal service conditions.
- Permanent charge 24h at 100% LF =1.0
- Conductor temperature 90 ° C
For cable laid in earth in tubes
- Depth of laying in soil : 1.0 m
- Max. soil temperatureempérature : 20 °C
- Soil thermal resistivity: 1.0 °C m/W
For cables placed in the open air
- Max. air temperature : 30 °C
- Protected from direct sunlight
- laid on consoles or cable trays
Grounding:
-
at one end, in this case the induced voltage increases proportionally with the length of the
the link.Attention, too high induced voltage can cause a breakdown of the outer sheath during overvoltages
transient. -
Either at both ends, which generates circulating currents and therefore more or less acceptable losses..
Correction factor
If the terms of service differ from those set out above, allowable currents must be corrected
taking into account all the correction factors that apply to the installation and service conditions encountered.
Main factors to consider are the following:
- Variable load, factor taking into account variable load, 10h to 100% and 14h to 60% LF= 0.627
- Operating temperature
- Ambient Temperature
- Thermal soil resistivity, factor taking into account the thermal resistivity of the soil in [°C * m / W]
- Magnetic armor
Our engineers are at your disposal to help and advise you.
Characteristics
Characteristics
Electrical characteristics
Electrical characteristics